| 1.01 |
SUMMARY |
| |
|
|
|
|
|
|
| |
A. |
Section
includes exterior overhead coiling storm and
security shutters.
|
| |
2. |
Related
Sections |
| |
|
1. |
Furnishing
Brass Push Lock |
| |
|
2. |
Division
No. 16 - Electrical: Electrical power, conduits,
field wiring and disconnect switches for motorized
shutters. |
| |
|
|
|
|
|
|
| 1.02 |
SUBMITTALS
|
| |
|
|
| |
A. |
Procedure:
Comply with requirements the Submittal Procedures.
|
| |
2. |
Product
Data: Submit manufacturer's complete product data
for all specified components, including specifications,
finish information and installation instructions.
|
| |
3. |
Shop
Drawings: Submit shop drawings showing layout,
sizes and types, product materials, components
and accessories, fabrication data, operation and
wiring diagrams for motor driven operators, finishes,
rough-in dimensions, anchorage and installation
requirements and details. |
| |
4. |
Samples:
Manufacture's standard selection of colors for
selection by the architect. |
| |
5. |
Quality
Assurance Submittals:
|
| |
|
1. |
Test
Reports: Certified test reports showing compliance
with specified requirements. |
| |
|
2. |
Certificates:
Manufacture's certification stating that design
criteria meets specified requirements. |
| |
|
3. |
Operating
and Maintenance Instructions: Submit detailed maintenance
requirements and operating instructions.
|
| |
|
4. |
Warranty:
Submit specified warranty documents. |
| |
|
|
|
|
|
|
| 1.03 |
QUALITY
ASSURANCE |
| |
|
|
| |
A. |
Installer
Qualifications:
|
| |
|
1. |
Use
only manufacturer's factory trained installers
or qualified licensed installer approved by the
shutter manufacturer. |
| |
2. |
Regulatory
Requirements: |
| |
|
1. |
Comply
with all local and governing code requirements. |
| |
|
2. |
Unless
required otherwise, fabricate to withstand wind
loads that carry same rating as component cladding
of the walls. |
| |
3. |
Pre-installation
Conference: Conduct a pre-installation meeting
to verify project installation and coordination
requirements, field conditions, and manufacture's
instructions. |
| |
|
|
|
|
|
|
| 1.04 |
DELIVERY,
STORAGE AND HANDLING |
| |
|
|
|
|
|
|
| |
A. |
Procedure:
Comply with Product Delivery Requirements.
|
| |
2. |
Deliver
components in manufacturer's original, unopened,
undamaged containers with identification labels
intact. Store components protected from harmful
weather conditions and damage from other construction
activities. |
| |
|
|
|
|
|
|
| 1.05 |
PROJECT
CONDITIONS |
| |
|
|
|
|
|
|
| |
A. |
Field
Measurements: Verify actual measurements of openings
by field measurements fabrication. Show recorded
measurements on shop drawings. |
| |
|
|
|
|
|
|
| 1.06 |
WARRANTY |
| |
|
|
|
|
|
|
| |
A. |
Manufacturer's
Warranty: Submit, for Owner's Acceptance, manufacturer's
standard warranty document executed by an authorized
company official.
|
| |
|
1. |
Warranty
period: ______years. |
| |
|
|
|
|
|
|
| (Specifier
Note: Refer to manufacturer's product data and/or
consult with manufacturer's representative for
warranty information/requirements). |
| |
|
|
|
|
|
|
| PART
2 - PRODUCTS |
| |
|
|
|
|
|
|
| (Specifier
Note: Typically in the following, where items occur
in brackets [ ] select the product appropriate
for the project being specified). |
| |
|
|
|
|
|
|
| 2.01 |
MANUFACTURER |
| |
|
|
|
|
|
|
| |
A. |
ACC
MANUFACTURING, LLC
1300 LAKE WASHINGTON ROAD
MELBOURNE, FL 32935
(877) 422-2634,
FAX (941) 274-3881 |
| |
|
|
|
|
|
|
| 2.02 |
MATERIALS |
| |
|
|
|
|
|
|
| |
A. |
Shutter
System: Provide VIKING Shutter System
|
| |
2. |
Shutter
Operation: Manual Operation |
| |
3. |
Shutter
Components |
| |
|
1. |
Hinged
Blades: Extruded Aluminum 6063-T6, Aluminum alloy. |
| |
|
2. |
Screws:
#14 X 2-3/4 inch; 410 HT Stainless Steel, with
JS500 Plating. |
| |
|
3. |
Provide
all required components as necessary for a complete
and properly operating installation for the shutter
system selected. Required components include but
are not limited to, hinged blades, wall header,
ceiling header, sill with the two-piece adjustable
sill system, roller assemblies with nylon roller/nylon
bushings, and locking mechanism. |
| |
|
4. |
Mounting:
[wall mounted] [build out mounted] [ceiling and
floor mounted] |
| |
|
|
|
|
|
|
| 2.03 |
SHOP
FINISH |
| |
|
|
|
|
|
|
| |
A. |
Blades
and tracks: (Electrostatically Applied - ESP-
paint Finish.
|
| |
2. |
Color:
[White] [Bronze] As selected by the architect.
|
| |
|
|
|
|
|
|
| 3.01 |
EXAMINATION
|
|
| |
|
|
|
|
|
|
| |
A. |
Verify
condition of substrates to determine if acceptable
for shutter installation in accordance with manufacturer's
instructions. Correct all unsatisfactory conditions
prior to commencing shutter installations.
|
| |
|
|
|
|
|
|
| 3.02 |
INSTALLATION |
|
| |
|
|
| |
A. |
Install
all shutter components to comply with project shop
drawings and manufacturer's written installation
requirements. |
| |
|
1. |
Where
metal surfaces are in contact with masonry, concrete
or dissimilar metals, protect per the manufacturer's
installation procedures with recommended isolation
coatings or tape. |
| |
2. |
After
installation, lubricate, test and adjust shutters
to ensure proper operation. |
| |
|
|
|
|
|
|
| 3.03 |
CLEANING
|
|
| |
|
|
|
|
|
|
| |
A. |
Clean
installed components in accordance with manufacturer's
instructions prior to Owner's acceptance. Properly
remove for the site all debris remaining from the
installation. |
| |
|
|
|
|
|
|
| 3.04 |
PROTECTION
|
|
|
| |
|
|
|
|
|
|
| |
A. |
Comply
with manufacturer's recommendation and protect
completed shutter installations from damage during
remaining construction so as not to void the warranty. |
| END